child beam

Tag Archive for: child beam

chilled beam application

chilled beam application

The use of strong induction property in the example of active chilled beams has caused the complete elimination of the fan compared to the fan coils, which causes the complete elimination of sound.

About 20% of the incoming air in these systems is provided by the air conditioner, which has already been silenced, and the remaining 80% enters the Chilled beam from the environment by the induction property (suction) produced by the Chilled beam.

Another type of child beam is its passive type – or cooling ceiling panels – which are used to cool the ceiling.

The simultaneous use of radiation properties has a significant effect on the significant increase in the working efficiency of child beams, especially its passive type.

In this type of child beam, without the intervention of a fan, the hot air goes up by the natural convection current and after hitting the coil and cooling, it moves down freely without the help of a fan and cools the ambient air.

In each Chilled beam cooling unit – of passive and active type – the water temperature between 15 and 17 degrees Celsius is pumped to Chilled beam by the water system in order to bring the ambient air temperature to the appropriate level.

The temperature of hot water in Active Chilled beam type is about 500 C, which makes it possible to use solar energy for heating in winter.

 

Performance of child beams of Active model

The main design of this type of chilled beams is in such a way that fresh air enters special air discharge nozzles with dynamic pressure, and as a result, the static pressure, which is lower, causes hot air to be drawn from the room to the chilled beams.

Inside the Chilled beam copper tube, cold water is passed for cooling, which consists of aluminum fins (coil), heat is absorbed through aluminum and cooled by cold water. Then the ambient heat is transferred to the water circuit through the copper pipe and returns to a central cooling unit. Also, a heating function can convert cold water copper pipes to hot water and thus heating ventilation.

 

انواع چیلد بیم

Performance of passive model child beams

The warm air inside the room is always on the surface of the cold air due to its lower density. The cold water passes through the cold rays of the child beam and cools the warm air above the room, and as a result, the cold air moves down due to its higher density (Drop phenomenon) and this cycle continues day and night to make the ambient air favorable. make

The general result is that these types of child beams can reduce the temperature of the environment without having a fan or even fresh air intake (optimizing energy consumption) and without making any noise.

In a cold rolling process, the copper tube is made efficient by metallurgical bonding to an aluminum sheet (Gills) which enables the transfer of energy from the cold surface to the water circuit and makes galvanic corrosion between the metallurgical bond of copper and aluminum impossible.

Shahrokhi Industrial Group

 

Silent ventilation, why and how؟

Functional equipment in silent ventilation

Silent ventilation, why and how?

Silent ventilation, why and how?

Silent fan coils

In this category of fan coils, by fully insulating the fan coil and also choosing the right fan and reducing the internal pressure drop, the sound caused by the fan is taken and thus the transmission of the fan sound to the environment is prevented.

فن کویل های صداگیر شده

Soundproof fan coils

VAV coils

This system can be used in environments with less thermal and cooling load and the need to limit the sound of the ventilation system, such as luxury places such as hotels, luxury conference halls and similar places.

The air in this system is supplied by the air generator, which has already been sounded.

 

VAV coil

VAV coil

Plenum boxes and modern air registers

A ventilation system must produce and distribute a certain volume of air to create favorable air conditions. On the other hand, parameters such as the amount of sound production, air speed and temperature in the room should also be considered. For this purpose, in the design and selection of the air distribution system in each room, the appropriate type of air register, the shape and speed of the air projectile at different temperatures should be calculated and considered in the design in order to create the desired conditions.

Today, different types of modern air registers such as induction, solar and low impulse registers – all equipped with plenum boxes – can be used with very low noise level, about 25-35 db(A), while the air registers that are used in Iran today for Hitting the right projectile often produces a high sound level of around 40-50 db(A).

 

 

پلنوم باکس ها و دریچه های مدرن

Plenum boxes and modern air registers

پلنوم باکس ها و دریچه های مدرن

Plenum boxes and modern air registers

Plenum boxes

There are different methods for transferring air from the channel to the registers, which can be changed depending on the design conditions and installation restrictions.

One of the prominent systems in this regard is the use of plenum boxes. Today, this system is widely used in modern ventilation due to its special advantages and capabilities.

 

Advantages of plenum boxes
  • Very high volume, especially in low frequencies

  • Smoothing the air flow before reaching the valve at low altitude

  • The possibility of using a damper to adjust the air

Sound Attenuator box fans

Nowadays, the role of insulated box fans in ventilation systems has become more and more colorful. It is very common to use this type of insulated fans – for example, in home ventilation systems.

باکس فن های صداگیر شده

Sound Attenuator box fans

Childbeams

The use of strong induction property in the example of active childbeams has caused the complete elimination of the fan compared to the fan coils, which causes the complete elimination of sound.

About 20% of the incoming air in these systems is supplied by the air conditioner, which is already sound-proofed, and the remaining 80% enters the Childbeam from the environment by the induction property (suction) produced by the Childbeam.

Another type of child beam is its Passive type (that is, cooling ceiling panels), which are used to cool the ceiling.

 

چیلدبیم ها

Childbeams

The simultaneous use of radiation properties has a significant effect on the significant increase in the working efficiency of child beams, especially its passive type. In this type of child beam, without the intervention of a fan, the hot air goes up by the natural convection current and after hitting the coil and cooling, it moves down freely without the help of a fan and cools the ambient air.

In each passive and active Childbeam cooling unit, the water temperature between 15 and 17 degrees Celsius is pumped to the Childbeam by the water system in order to bring the ambient air temperature to the appropriate level.

The temperature of hot water in Active Childbeam type is around 50 degrees Celsius, which makes it possible to use solar energy for heating in winter.

 

Application level of this equipment

In the end, it is important to mention that all the equipment mentioned in this article have been used for many years as complementary components of the ventilation system in developed countries on a large scale. For example, the newest example of this equipment, namely Child Beams, entered the market more than fifteen years ago and today they are widely used in various types of ventilation systems, especially in European countries.